EasyManuals Logo

Honeywell OMNI 624 User Manual

Honeywell OMNI 624
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
Section 5. System Operation
5–9
Level Functions Allowed
1 Primary Master can view log and set time, assign other user codes, all system functions
2 Secondary Master, same as primary Master except cannot change the primary Masters code
3 User, can arm and disarm only
4 Limited user, same as level 3, except can disarm the system only if it was armed by another user with level
4 authority (cannot disarm if armed with user of higher authority level).
4/6-DIGIT USER CODES
The system supports either 4- or 6-digit user codes. A bit option in Submode 1, Question 12, Location 3
selects if the user codes are to be 4 or 6 digits in length for the entire system. The default user code for
the master is 1234 with an authority level of 1. The system is defaulted to 4-digit user/installer code. If
the bit is set in installer mode, each currently programmed code will change to six digits by adding a
“00" before the known 4-digit code.
For example, if 4-digit codes are being changed to 6 digits and a user code was 1-2-3-4, it will become 0-
0-1-2-3-4. Conversely, if the user code length was 6, and it is changed back to 4 digits, the code 1-2-3-4-
5-6 will become 3-4-5-6.
Once “6-digit user codes” is selected, new codes entered can be any combination of 6 digits.
NOTE: Selecting 6-digit user codes also affects the installer code by adding 00 to the code (default installer code 2468
becomes 002468). Use Question 00 to enter a new installer code.
TO ADD OR CHANGE USERS:
Press [CODE] + MASTER USER CODE + USER NO. + NEW USER CODE + AUTHORITY LEVEL
where:
[CODE] [CODE] button on keypad.
MASTER USER 4- or 6-digit* Master User code (user with authority level 1 or 2)
USER NO. Desired user number to be programmed (01–32).
NEW USER CODE 4- or 6-digit* user code for the new user. Valid digits are 0–9.
AUTHORITY LEVEL The desired authority level for the new user.
*(Depending on the whether the system is set for 4- or 6-digit security codes)
EXAMPLE: Define user number 03 with a code of 7493 and authority level 3. (Assume Master code is
1234) = CODE 1234 03 7493 3
An acknowledgment (steady tone) verifies a successful user code programming. A negative
acknowledgment (4 short tones) indicates unsuccessful programming. If additional user programming
is necessary, repeat the procedure listed above. If a dialing format is programmed that transmits
opening/closing by user ID, each user will report their user number.
ASSIGNING PARTITIONS AND PAGER OPEN/CLOSE REPORTS TO USERS
Users are automatically enabled for the partition where their code was added. You can also allow users
to access other partitions and/or enable open/close pager reports for a user by using the #7 command as
follows:
[#] + [7] + MASTER USER CODE + USER NO. + [1], [2], or [4]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell OMNI 624 and is the answer not in the manual?

Honeywell OMNI 624 Specifications

General IconGeneral
BrandHoneywell
ModelOMNI 624
CategorySecurity System
LanguageEnglish

Related product manuals