EasyManuals Logo

Honeywell OMNI 624 User Manual

Honeywell OMNI 624
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #71 background imageLoading...
Page #71 background image
Section 6. System Programming
6–33
Q 23, L4 Pager Enables for Partitions and Follow Me
L4
Entry
Enable User
Page Part. 1
Enable User
Page Part. 2
Enable #58
Follow Me
0
1
2
3
8
9
A
B
Enable User Page Part. 1–2: If selected, the open
and/or close events selected in L1–L2 above will be
reported to a pager for users in a particular partition.
This setting can be toggled by using the #8 command.
Enable #58 Follow Me: If selected, enables the #58
Quick Command. The #58 Quick command is used to
modify the pager telephone number from the keypad.
QUESTION 24 KEYPAD TAMPER, NO ARM, AND RF JAM N/U
L1 L2 L3 L4
Tamper No Arm Jam
Q 24, L2 Keypad Tamper
This question controls keypad tamper and the alerts sounded on a keypad tamper condition.
L2
Entry
Keypad
Tamper
Enable
Keypad
Tamper
Sounder
Keypad
Tamper
Bell
0
1
3
5
Keypad Tamper Enable: If enabled, the system will monitor
the keypads for a keypad tamper report. If a keypad tamper is
reported by a keypad, a report will be sent to the central station
if enabled in Submode 2, Question 43, Locations 3 and 4.
Keypad Tamper Sounder: If enabled, the keypad sounder
will sound on a keypad tamper condition.
Keypad Tamper Bell: If enabled, the keypad sounder and bell
will sound on a keypad tamper condition.
NOTE: Keypad tamper is only available on some OMNI-LCD, OMNI-LCD-US, OMNI-KP, and OMNI-
KP-US keypads. Refer to your keypad instructions to see if your keypad has keypad tamper detection
capabilities.
Q 24, L3 No Arm if Jam, Supervision, or AC
This question controls arming while in a jam, supervision, or no AC condition.
L3
Entry
No Arm
if RF Jam
No Arm
if Super
No
AC/2X
0
1
3
5
7
No Arm if RF Jam: If selected, when the user tries to arm
the system when in a jam condition, the system will provide a
negative acknowledgement and will not arm.
No Arm if Super: If selected, when the user tries to arm the
system and a supervised RF zone is in a supervision condition,
the system will provide a negative acknowledgement and will
not arm.
No AC/2X: If selected, when the user tries to arm the system
with an AC fail condition, the system will provide a negative
acknowledgement and will not arm. To arm the system, the
user must enter their code a second time.