Section 6. System Programming
6–33
Q 23, L4 – Pager Enables for Partitions and Follow Me
L4
Entry
Enable User
Page Part. 1
Enable User
Page Part. 2
Enable #58
Follow Me
0
1
✔
2
✔
3
✔ ✔
8
✔
9
✔ ✔
A
✔ ✔
B
✔ ✔ ✔
Enable User Page Part. 1–2: If selected, the open
and/or close events selected in L1–L2 above will be
reported to a pager for users in a particular partition.
This setting can be toggled by using the #8 command.
Enable #58 Follow Me: If selected, enables the #58
Quick Command. The #58 Quick command is used to
modify the pager telephone number from the keypad.
QUESTION 24 KEYPAD TAMPER, NO ARM, AND RF JAM N/U
L1 L2 L3 L4
Tamper No Arm Jam
Q 24, L2 – Keypad Tamper
This question controls keypad tamper and the alerts sounded on a keypad tamper condition.
L2
Entry
Keypad
Tamper
Enable
Keypad
Tamper
Sounder
Keypad
Tamper
Bell
0
1
✔
3
✔ ✔
5
✔ ✔ ✔
Keypad Tamper Enable: If enabled, the system will monitor
the keypads for a keypad tamper report. If a keypad tamper is
reported by a keypad, a report will be sent to the central station
if enabled in Submode 2, Question 43, Locations 3 and 4.
Keypad Tamper Sounder: If enabled, the keypad sounder
will sound on a keypad tamper condition.
Keypad Tamper Bell: If enabled, the keypad sounder and bell
will sound on a keypad tamper condition.
NOTE: Keypad tamper is only available on some OMNI-LCD, OMNI-LCD-US, OMNI-KP, and OMNI-
KP-US keypads. Refer to your keypad instructions to see if your keypad has keypad tamper detection
capabilities.
Q 24, L3 – No Arm if Jam, Supervision, or AC
This question controls arming while in a jam, supervision, or no AC condition.
L3
Entry
No Arm
if RF Jam
No Arm
if Super
No
AC/2X
0
1
✔
3
✔ ✔
5
✔
✔
7
✔ ✔ ✔
No Arm if RF Jam: If selected, when the user tries to arm
the system when in a jam condition, the system will provide a
negative acknowledgement and will not arm.
No Arm if Super: If selected, when the user tries to arm the
system and a supervised RF zone is in a supervision condition,
the system will provide a negative acknowledgement and will
not arm.
No AC/2X: If selected, when the user tries to arm the system
with an AC fail condition, the system will provide a negative
acknowledgement and will not arm. To arm the system, the
user must enter their code a second time.