EN2R-9031 0402R15-NE 44
Fig. 53. Connection diagram S4565RV and TV with prepurge option
Fig. 54. Alternative side connection in case of combined
flame sensing and sparking
Fig. 55. Alternative side connection in case of sparking
to ground
Fig. 56. Connection for opto coupler output Fig. 57. Alternative side connection for external
AC1A199.01 igniter
N
Side connections *
Optional **
LM
Status output or
relay contact
P
NL
12
11
10
9
8
76 5
421
* See page 44. Fig. 55.
** See page 44. Fig. 56.
Side connections
Side connections
2 1
5V
Flame
output
10k
+-
Side connections
AC1A199.01