APPENDICES
Standpipe
Cond
e
nsate
Pump
Sump
Laundry
Tub
Drain points for reject water
Floor
Drain
Cold Water Supply
MCR35331
1/4” White Tubing
Manual Shutoff Valve
Backflow
Preventer
White Tubing
Red Tubing
Drainflow Control
Plug
Setting up the RO Filter
See the instruction sheet packaged with the RO Filtration System for complete installation instructions.
1. Mount the base chassis to a surface capable
of holding up to 7 pounds between the home’s
cold water line and the steam humidier
location. (Mounting hardware is provided.)
2. Connect the 1/4-inch white water line to the
home’s main cold water supply. Connect the
other end to the inlet port on the base chassis.
3. Connect the 1/4-inch white water line to the
outlet on the base chassis. Connect the other
end to the backow preventer. Connect another
water line between the backow preventer and
the steam humidier supply tting.
4. Connect the red tubing to the reject water port
on the base chassis, and to a suitable drain on
the other end.
IMPORTANT: Refer to and follow local codes
for proper drain installation. Refer to additional
drain requirements in the steam humidier
installation guide when coupling the RO Filter
drain with the steam humidier drain.
4
1
2
2
6
3
3
4
Steam Humidier System 69-2285—09 25