WIRING
IMPORTANT NOTE: The images below are not complete wiring diagrams. It only depicts power monitoring and is not
meant to be a stand alone diagram. Please refer to the “Wiring the steam humidier” section in the following pages for
complete wiring diagrams.
WIRING BASICS: CONFIGURATION 1
When using a thermostat with integrated
humidity control (such as VisionPRO IAQ
or Prestige):
• A thermostat controls the fan and steam
humidier. The control will not allow steam
production unless the system fan
is on.
• Wire Thermostat G to the HVAC system G
as normal.
• Wire steam humidier HUM terminals to
the system HUM terminals.
WIRING BASICS: CONFIGURATION 2
When using a humidistat separate from the
thermostat (such as H6062 or TrueIAQ):
• The external humidity control does not
monitor or control the system fan. Steam
humidier must conrm that the fan has
power before allowing humidity.
• Break the thermostat G to HVAC system
G connection. Wire thermostat G to steam
humidier GT. Wire steam humidier GF to
HVAC system G.
• Thermostat G calls will pass directly
through steam humidier. If this signal is
not present, and humidity is needed, steam
humidier will relay power from its RT
terminal to GF and out to HVAC system
G to ensure the fan has power for
humidity calls.
Thermostat with
Humidity Control
HVAC System
Steam Humidifier
1
HUM
HUM
2 3
R
C
M29617A
Humidity Control
Thermostat
Steam Humidifier
HVAC System
HUM
HUM
R
G
GT
GGF