OPERATION
AND SERVICE
The cleaning ush cycle is initiated when the Draining
light begins blinking. The cycle will take about
45 minutes to complete. It will take longer if using
RO lters.
When the Empty light is on, the tank is empty. The tank
may now be removed for cleaning or
other service.
Be sure to disconnect the steam humidier from power
before beginning the cleaning procedure
M29628A
M29629A
CAUTION: Scalding hazard.
If you override the cooling action of the ush cycle, the tank will empty immediately,
regardless of water temperature. Make sure the drain can handle up to 212°F (100°C) if
you do this.
During manual drain, initial water temperature may be above 140°F (60°C). Scalding water
could splash out of the drain. Use caution when pressing the Drain button.
BEST
PRACTICE
Perform all cleaning steps at least once per humidication
season.
Steam Humidier System 69-2285—09 45