EasyManuals Logo

Honeywell V4730C Operating Instructions

Honeywell V4730C
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
V4730C/V8730C/V4734C · Edition 05.23
EN-10
10.5 Sensing tube VMU
Short Sensing Tube for VMU150/300/335kW Ven-
turi Mixing Units. Order No.: KTTBA001.
Long Sensing Tube for VMU500kW Venturi Mixing
Unit. Order No.: KTTBA002.
10.6 Manual Shut-Off Valve
Manual Shut-Off Valve Kits can be ordered to pro-
vide manual shut-off function.
Order no.: 50002653-001, for 1inch NPT or smaller
valves.
Order no.: 50002653-002, for 1-1/4inch NPT valve.
10.7 Pressure switch for gas C60VR4
The pressure switch for gas monitors the inlet pres-
sure or the intermediate pressure.
inlet pressure
intermediate pressure
Scope of delivery:
1xpressure switch for gas,
2xself-tapping retaining screws,
1xsealing ring,
1xprotection cap.
10.7.1 Pressure switch connection plug
Electrical connections Standard DIN plug connector
according DIN43650 (Form A)
-CO020014 (gray). Not included.
10.7.2 Adjust switching point
The switching point is adjustable via hand wheel.
1
2
3
Type
Adjusting
range
(adjusting
tolerance =
±15% of the
scale value)
Mean
switching
differential at
min. and max.
setting
[mbar] ["WC] [mbar] ["WC]
C60VRT40040
5–40 2–16 1–2 0,4–1
Deviation from the switching point during testing
pursuant to EN1854 Gas pressure switches:
±15%.
11 TECHNICAL DATA
The specifications in this section are related to the
Venturi Mixing Unit (VMU) and Combination Gas
Valve.
Valve and flange size:
Type Valve size Flange size
V4730C1006 1/2" 1/2"
V4730C1014 3/4" 3/4"
V4730C1022 1" 1"
V4730C1030 1" 1 1/4"
V4734C1002 1 1/4" 1 1/4"
V8730C1007 1/2" 1/2"
V8730C1015 3/4" 3/4"
V8730C1023 1" 1"
V8730C1031 1" 1 1/4"
Power consumption:
Type Voltage
V1 + V2,
total current
V4730C1006
V4730C1014
120V AC,
50/60Hz
0.26A
V4730C1022
V4730C1030
120V AC,
50/60Hz
0.46A
V4734C1002
120V AC,
50/60Hz
0.8A at
startup
0.26A
1)
V8730C1007
V8730C1015
24V AC,
50/60Hz
1.28A
V8730C1023
V8730C1031
24V AC,
50/60Hz
3.0A
1) First value during start up, second value
during normal operation

Other manuals for Honeywell V4730C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell V4730C and is the answer not in the manual?

Honeywell V4730C Specifications

General IconGeneral
BrandHoneywell
ModelV4730C
CategoryControl Unit
LanguageEnglish

Related product manuals