EasyManua.ls Logo

Honeywell Voyager 1452g Series - RS232 Word Length: Data Bits, Stop Bits, and Parity

Honeywell Voyager 1452g Series
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 - 19
RS232 Word Length: Data Bits, Stop Bits, and Parity
Data Bits sets the word length at 7 or 8 bits of data per character. If an application requires only ASCII Hex characters 0
through 7F decimal (text, digits, and punctuation), select 7 data bits. For applications that require use of the full ASCII set,
select 8 data bits per character. Default = 8.
Stop Bits sets the stop bits at 1 or 2. Default = 1.
Parity provides a means of checking character bit patterns for validity.
Default = None.
1200
2400
4800
* 9600
19200
38400
57,600
115,200
7 Data, 1 Stop, Parity Even

Table of Contents