EasyManua.ls Logo

Honeywell Voyager XP 1472g Series - Depth of Field Charts; Typical Performance

Honeywell Voyager XP 1472g Series
246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
200 Voyager 1470/1472 User Guide
Depth of Field Charts
Typical Performance
Mechanical Drop Operational after 50 drops from 3.28 feet
(1 m) to concrete
Vibration 5G Peak from 22Hz to 300Hz
ESD Sensitivity Up to 15kV direct air
Up to 8 kV indirect coupling plane
Sealant Rating IP41
(Continued)Parameter Specification
Focus
Symbology
Near
Distance
Far
Distance
5 mil Code 39 in. .8 8.1
mm 20 205
10 mil Code 39 in. .2 14.4
mm 5 365
13 mil UPC-A in. .7 15.7
mm 18 400
20 mil Code 39 in. 1 24.2
mm 25 615
6.7 mil PDF417 in. .6 7.3
mm 15 185
10 mil PDF417 in. .8 11
mm 20 280
10 mil Data Matrix in. .4 6.5
mm 10 165
10 mil QR Code in. .2 6.9
mm 5 175
20 mil QR Code in. .2 12.8
mm 5 325
NYS DL in. 3.1 8.7
mm 80 220