208 Voyager 1470/1472 User Guide
Replace Cables in Corded Scanners
The standard interface cable is attached to the scanner with an 10-pin modular
connector. When properly seated, the connector is held in the scanner’s handle by
a flexible retention tab. The interface cable is designed to be field replaceable.
• Order replacement cables from Honeywell or from an authorized distributor.
• When ordering a replacement cable, specify the cable part number of the
original interface cable.
Replace a Corded Scanner Interface Cable
1. Turn the power to the host system OFF.
2. Disconnect the scanner’s cable from the terminal or
computer.
3. Locate the small hole on the back of the scanner’s handle.
This is the cable release.
4. Straighten one end of a paper clip.
5. Insert the end of the paper clip into the small hole and press
in. This depresses the retention tab, releasing the connector.
Pull the connector out while maintaining pressure on the
paper clip, then remove the paper clip.
6. Replace with the new cable.
Insert the connector into the opening and press firmly. The
connector is keyed to go in only one way, and will click into
place.
Replace Cables and Batteries in Cordless Systems
Replace an Interface Cable in a Base
1. Turn the power to the host system OFF.
2. Disconnect the base’s cable from the terminal or computer.
3. Turn the base upside down.