3 - 36
Relink Time-Out
Relink Time-Out controls the idle time between relink attempts.  An attempt 
to link a scanner to a base or an Access Point typically lasts up to 5 sec-
onds.  This is the time when the scanner is actually attempting a contact .  
Relink Time-Out controls the amount of time, in seconds, that elapses 
between the end of one connection attempt and the start of the next.
Note: The length of time for an attempt depends on the number of scanners 
connected to a base unit or Access Point.  An extra 7 seconds may 
be required when a connection is successful.
Scan the Relink Time-Out bar code, then scan the number of seconds for 
the setting (from 1-100) from the inside back cover.  Scan Save to save the 
setting.  
Default = 3 seconds.
Bluetooth/ISM Network Activity Examples
Default values
When the scanner goes out of range, the scanner repeatedly attempts to 
connect to the base unit or Access Point.  Each attempt consists of approx-
imately 5 seconds of active time followed by 3 seconds of idle time.  After 
one hour, the scanner powers off and batch mode data is lost.
Maximum Link Attempts set to 15
Other values at default setting
When the scanner goes out of range, 15 attempts are made to link to the 
base unit or Access Point.  Each attempt consists of approximately 5 sec-
onds of active time followed by 3 seconds of idle time.  After 15 cycles 
(8*15 =120), or about 2 minutes, the scanner stops trying to connect to the 
base or Access Point, but retains any bar codes that may have been saved 
in batch mode.  After one hour, the scanner powers off and batch mode 
data is lost.
Auto Reconnect Mode set to 0
Maximum Link Attempts set to 15
Other values at default setting
When the scanner goes out of range, no action is taken to relink.  When  
the trigger is pulled, 15 attempts are made to link to the base or Access 
Point.  Each attempt consists of approximately 5 seconds of active time fol-
lowed by 3 seconds of idle time.  After 15 cycles (8*15 =120), or about 2 
minutes, the scanner stops trying to connect to the base or Access Point, 
but retains any bar codes that may have been saved in batch mode.  After 
one hour, the scanner powers off and batch mode data is lost. Refer to 
Auto Reconnect Mode, page 3-34, to review other events that can start the 
relink process.