EasyManuals Logo

Hoymiles HMT-2250-6T User Manual

Hoymiles HMT-2250-6T
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
8.1 DC Input
Model HMT-1800-6T HMT-2500-6T
Commonly used module power (W)
Up to 380
(single panel)
Up to 470
(singe panel)
Peak power MPPT voltage range (V) 29~48 36~48
Start-up voltage (V) 22 22
Operating voltage range (V) 16~60 16~60
Maximum input voltage (V) 60 60
Maximum input current (A) 6*11.5 6*11.5
Maximum input short circuit current (A) 6*15 6*15
8.2 AC Output
Model HMT-18 0 0-6T HMT-2500-6T
Grid connection Three phase
Rated output power (VA) 1800 2500
Rated output current (A)
3*2.73@220V
3*2.61@230V
3*3.41@220V
3*3.26@230V
Nominal output voltage (V)
220Vac/380Vac, 230Vac/400Vac, 3W+N+PE
16~60
Nominal frequency (Hz) 50/60
Power factor
>0.99 default
0.8 leading……0.8 lagging
Output current harmonic distortion <3% <3%
Maximum units per 12AWG branch
7@220V
7@230V
5@220V
6@230V
Maximum units per 10AWG branch
11@220V
11@230V
8@220V
9@230V
© 2020 Hoymiles Power Electronics Inc. All rights reserved.
20
Three-phase Microinverter HMT-1800/2250 Technical Data
8. Technical Data
Warning: Be sure to verify the following before installing Hoymiles Microinverter System.
Verify that the voltage and current specications of the PV module must match those of the
microinverter.
The maximum open circuit voltage rating of the PV module must within the operating voltage range
of the microinverter.
The maximum current rating at MPP is recommended to be equal to or less than the maximum input
DC current. But the maximum short circuit current must be equal to or less than the maximum
input DC short circuit current.
The output DC power of PV module is NOT recommended to exceed 1.35 times the output
AC power of the microinverter. Refer to “Hoymiles Warranty Terms & Conditions” for more
information.

Other manuals for Hoymiles HMT-2250-6T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hoymiles HMT-2250-6T and is the answer not in the manual?

Hoymiles HMT-2250-6T Specifications

General IconGeneral
ModelHMT-2250-6T
CategoryInverter
Max. Output Power2250 W
Number of MPPTs6
Efficiency96.5%
Peak Power Tracking Voltage Range16-60 V
Startup Voltage22 V
Rated Output Power2250 W
Rated Output Current9.78A
Nominal Output Voltage/Range230 V
Rated Output Voltage230 V
Output Frequency50/60 Hz
Cooling MethodNatural Convection
Protection LevelIP67
Maximum Input Current12A
Ambient Temperature Range-40°C to +60°C
Operating Temperature Range-40°C to +60°C

Related product manuals