Adjustments
Model 182C
5-25.
LOWVOLTAGE
POWER
SUPPLY.
a. Connect Digital Voltmeter to +100V testpoint
A1A2TP1 (Figure 5-2).
b. Set -MOOV adjust A1A2R11 to obtain a reading of
+100V tO.1V.
c.
Connect Digital Voltmeter
to
+15V testpoint
A1A2
TP2.
(1. Set +15V adjust A1A7R20 to obtain a reading of
M5V
tO.1V.
e. Connect Digital Voltmeter to
—12.6V testpoint
A1A2
TP3.
t- Set —12.6V
adjust A1A2R29 to
obtain a reading of
-12.6V +0.1V.
g.
Connect Digital Voltmeter to -100V testpoint
A1A2TP4.
h. Set
-100V adjust A1A2R40 to obtain a reading ot
-100V
to.iv.