2-23
IPv6 Management Features
SNMP Management for IPv6
The show snmp-server command displays the current SNMP policy
configuration, including SNMP communities, network security notifications,
link-change traps, trap receivers (including the IPv4 or IPv6 address) that can
receive SNMPv1 and SNMPv2c traps, and the source IP (interface) address
used in IP headers when sending SNMP notifications (traps and informs) or
responses to SNMP requests.
Figure 2-8.  “show snmp-server” Command Output with IPv6 Address
HP Switch(config)# show snmp-server
 SNMP Communities
 
  Community Name       MIB View Write Access
  -------------------- -------- ------------
  public               Manager  Unrestricted
  marker               Manager  Unrestricted
 
 Trap Receivers
 
  Link-Change Traps Enabled on Ports [All] : All
 
  Traps Category                  Current Status 
  ----------------------------    ---------------
  SNMP Authentication           : Extended 
  Password change               : Enabled 
  Login failures                : Enabled 
  Port-Security                 : Enabled 
  Authorization Server Contact  : Enabled 
 
  Address                Community              Events   Type   Retry   Timeout
  ---------------------- ---------------------- -------- ------ ------- -------
  15.29.17.218           public                 All      trap   3       15     
  15.29.17.219           public                 Critical trap   3       15     
  2620:0000:0260:0211
    :0217:a4ff:feff:1f70 marker                 Critical trap   3       15     
 
 
 Excluded MIBs
 
 Snmp Response Pdu Source-IP Information
 
  Selection Policy   : rfc1517             
 
 Trap Pdu Source-IP Information
 
  Selection Policy   : rfc1517             
SNMPv2c Inform 
configuration 
An IPv6 address is 
displayed on two lines.