3-127
Performance Tests
Performance Test Record
Step 14: 1.544Mb/s 0 ppm -4.5 ppm +4.5 ppm
Step 14: 1.544Mb/s -100 ppm -95.5 ppm -104.5 ppm
Step 14: 1.544Mb/s +100 ppm +95.5 ppm +104.5 ppm
Step 14: 44.736Mb/s 0 ppm -4.5 ppm +4.5 ppm
Step 14: 44.736Mb/s -100 ppm -95.5 ppm -104.5 ppm
Step 14: 44.736Mb/s+100 ppm +95.5 ppm +104.5 ppm
3-58
SDH/SONET Transmitter
Clock Accuracy
Step 4: Frequency 51.839670 MHz 51.840230 MHz
3-59 External MTS Clock
Step 7: 2Mb/s Clock Pass/Fail
Step 9: Ref Clock Out Pass/Fail
Step 16: 2Mb/s Data Pass/Fail
Step 21: 2Mb/s Data Balanced Pass/Fail
Step 25: Rx Data Clock Loss Pass/Fail
Step 28: Rx Data Clock Gain Pass/Fail
Step 30: 10 MHz Clock Loss Pass/Fail
Step 33: 10MHz Clock Gain Pass/Fail
Step 35: BITS Clock Loss Pass/Fail
Step 38: BITS Clock Gain Pass/Fail
Step 41: 64kb/s Clock Loss Pass/Fail
Step 42: 64kb/s Clock Gain Pass/Fail
3-64
SDH/SONET Offsets
Step 5: Clock Loss Pass/Fail
Step 10: 0ppm 51.84MHz
Step 11: -999ppm 51.7882108MHz 51.7882129MHz
Table 6 Performance Test Record continued
Page
No.
Test Description Result
Min Actual Max