Model
4262A
Successively,
the
D
measurement
cycle
begins.
The
D
autoranging
recycle
is
done
or
repeats
once
to
set
instrument
to
appropriate
D
range.
After
an
offset
null
sequence
for
D
measurement,
the
integrator
begins
to
charge
its
incoming
voltage
being
proportional
to
the
conductance
or
resist-
ance
of
the
DUT.
Discharge
time
is
proportional
to
the
reactance
of
the
DUT.
To
calculate
the
ratio
of
the
real
to
the
imaginary
part
of
the
DUT
current
(voltage
across
DUT
when
circuit
mode
is
SER),
the
integrator
is
charged
when
the
detection
phase
of
the
detected
output
is
at
“90”
degrees.
In
R
measurements,
the
D
measurement
cycle
is
omitted.
Since
the
electrical
response
time
for
each
measurement
frequency
is
different
and
the
charge
cycle
time
is
sometimes
a
function
of
this
frequency,
the
sequence
execute
times
are
different
for
measurement
frequencies
of
120Hz,
1kHz
and
10kHz.
Note
that
the
execute
time
for
the
discharge
sequence
is
variable.
8-36.
The
table
shown
in
the
lower
part
of
the
diagram
explains
how
voltage
Em
is
selected
by
the
instrument
(either
from
voltage
across
Rr
or
the
voltage
across
the
UNKNOWN)
and
how
the
de-
tection
phase
for
the
phase
detection,
employed
in
either
PRL
and
SER
circuit
modes,
is
selected.
Both
upper
and
lower
sections
of
the
waveform
timing
diagram
have
the
same
time
scale.
-€x,
-€x/10,
-ey
and
-€y/10
in
the
€m
column
are
names
for
voltages
shown
in
diagram
Note
2.
Diagram
Note
3
shows
the
phase
relationships
of
the
voltages
applied
to
phase
detector
FET
switches
A14Q19,
Q20,
Q22
and
Q23
(detection
phase)
along
with
the
phase
of
€ref
signal
at
A14
TP5.
The
detection
phase
is
sequentially
selected
by
PHASE
control
signals
(¢~3n/2)
which
are
transmitted
to
4
Phase
Selector
on
Al4
board
(from
A23
Nanoprocessor
&
ROM
board).
Note
Labels
H1
through
H10
in
the
tim-
ing
diagram
denote
the
timing
for
trigger
used
when
troubleshooting
instrument
using
A23
service
board
(service
kit
04262-87001).
The
4262A
measurement
sequence
can
be
stopped
at
or
resumed
from
the
desired
point
from
among
these
triggering
points
by
pushing
specific
4262A
front
panel
buttons.
Note
1.
Unit
for
excute
time
is
msec
except
for
discharge
sequence.
Note
2.
Selection
of
€p.
"
EvL
N
E2
\
Ro
r)I
ki
:\
Rg
/
)
v
N
-
a—
v
em
VSEL
1*
|
VSEL2*
-ex
0
0
-
ey
1
[}
-ex/10
0
1
ey/10
1
1
*
Gating
signals
for
Al3
FET
switches.
Note
3.
Phase
for
Phase
Detector
err
_
[
L[
L[
L
(A14TP5)
(N
Gy
U
/2
e
Rl
EEEEE
Note
4.
When
dissipation
factor
range
is
20,
the
-€x and
-y
are
attenuated
by
1/10.
Section
VIII
Figure
8-8
r
MEASUREMENT
CYCLE
w
s
L/C/R
MEASUREMENT
D/Q
MEASUREMENT
E—
\PPED
OVER
THIS
PERIOD
o
LCR
AUTO
RANGING
RECYCLE
e
S
RtuErT
UNCAL
G
AUTORANGING
RECYCLE
——
INTEGRA’)TOR
OUTPUT
=
(AI4TPI
-
_
o
w
3
3
g5
4=
g
Y
3
.
¥
3
z
of
TW
$&
o
<
o
«
=
o
o
o<
c
[
Jaz
as
)
z
J
I
[
r}
4
|
x
o
[
o
AF
=
o
o
o
L
o
<
oo
I
Il
ow
Oow
T
I
(Lh>
(7]
I
I
I|o
K_’
s
ED
E3
FUNCTION
8
CKT
MODE
12
u
S
=
v
i
%
aad
a
o
S
O32,5/count
©
Excute
Time*'
|KHz
o
<li<0l
42
Cp,LsiCs,Lp|
Rs
|
Rp.
o
S
A
N\
FREQUENCY
|OKH2”
37ms
IRE
30
11501
S
1321
3
PN
37,5
count
T7mb
3
32
6
30ms
120Hz
To0mS
125
240
42)
5
132)
3
Paa"
3zus/count
loonis
%4
32
T
30mS
32uS/count
RESET
(A23
SL)
-u
OFFSET
NULL
(A23pin
IL)
I
APA
|
(A23
pinAL)
APA
2
(A23pin2L)
:
STN
(A23pin3L)
:
SAT
(AI3pin9R)
:
|
e
1
i
)
!
11
!
{H1
H2
H3
H4
H5
HE
H7
H8
HO
HIO
|
I
I
-
]
£7
-€
»2]
Ls
—ex
I
~€y/10
|
-ex
~ey/10
|
-€x
—oX
Ls,
Cp
|
Cp
%
-y
|
-ex/10
]
-€y
~ex/10
|
-ey*1
I
ey
Ehose
tor
Prass
|
e
2’
2
|
}
-
-ex
»2|
Cs_1
-€X
I
-ey/10
ex*4
Lp,Cs|
€m
[Tp
|
ey
I
~ex/10
—ey*4
ey
rors
for
e
|
I
o
"
j—————
=
|
Rs
em.’ZI
Rs
|
-€x
I
-ey/10
-ex
I
-ey/10
e
sl
/2
[
S
U
"
___
|
Rp
em'zl
Rp
:
-ey
|
-ex/10
l
-ey
-ey
Phase
for
Phase
|
7/2
|
7
|
I
w2
Detector
e
e
—E———,—
T
T
T
T
T
T
T
T
T
T
T
T
T
Figure
8-8.
Timing
Diagram.
8-13

Table of Contents

Other manuals for HP 4262A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 4262A and is the answer not in the manual?

HP 4262A Specifications

General IconGeneral
BrandHP
Model4262A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals