Risks
Single path failure may result in data loss or disk corruption.
NOTE: For additional risks, see “VMware failure scenarios (page 130).
Limitations
HP P6000 Continuous Access is not supported with single path configurations.
Single path HBA server is not part of a cluster.
Booting from the SAN is supported on single path HBA servers.
Figure 40 VMware configuration
5 SAN switch 11 Network interconnection
6 SAN switch 22 Single HBA server
7 Controller A3 Dual HBA server
8 Controller B4 Management server
Failure scenarios
HP-UX
Table 29 HP-UX failure scenarios
Failure effectFault stimulus
Extremely critical event on UNIX. Can cause loss of system disk.Server failure (host power-cycled)
Short term: Data transfer stops. Possible I/O errors.
Long term: Job hangs, cannot umount disk, fsck failed, disk corrupted,
need mkfs disk.
Switch failure (SAN switch disabled)
Failure scenarios 127