Table 10 Maximum LUN size (continued)
Maximum LUN sizeOperating system
2 TBHP-UX 11.11
2 TBHP-UX 11.23
16 ZBHP-UX 11.31
1 TB (AIX 5.2ML06 or earlier)
2 ZB (AIX 5.2ML07 or later)
IBM AIX 5.2
1 TB (AIX 5.3ML02 or earlier)
2 ZB (AIX 5.3ML03 or later)
IBM AIX 5.3
2 ZBIBM AIX 6.1
Less than 32 TBMac OS X 10.x
Less than 32 TBMac OS X 11.x
256 TBMicrosoft Windows Server 2003
256 TBMicrosoft Windows Server 2008
Maximum supported block device at 16 TB as of RH5.1Red Hat Linux 3, 4, and 5
Maximum block device size is 16 TB for 32-bit system and
8 iEB for 64-bit systems
SUSE Linux Enterprise Server 8, 9, and 10
2 TBSun Solaris 8, 9, and 10
2 TBVMware ESX 3.0.x and 3.5
Maximum supported block device at 16 TBCitrix Xen
Managing unused ports
When you have unused ports on an EVA, perform the following steps:
1. Place a loopback plug on all unused ports.
2. Change the mode on unused ports from fabric to direct connect.
Changing the host port connectivity
To change the host port connectivity:
1. Disconnect any connected cable.
NOTE: Failing to disconnect the cable prior to making the change will require a controller
restart to clear the condition.
2. Use the OCP and navigate to the host port to be changed.
3. Select fabric for an FC switch connection or direct for direct attachment to an HBA.
4. Reconnect cables.
36 EVA6400/8400 operation