Chapter 8 Cabling and technology information 67
10GBASE-CR
(Direct Attach)
twinaxial copper N/A (various lengths offered)
10GBASE-SR multimode fiber 160 MHz*km
200 MHz*km
400 MHz*km
500 MHz*km
2000 MHz*km
2 - 26 meters
2 - 33 meters
2 - 66 meters
2 - 82 meters
2 - 300 meters
10GBASE-LR single mode fiber N/A 2 - 10,000 meters
10GBASE-ER single mode fiber N/A
2 - 40,000 meters
3
25GBASE-CR twinaxial copper N/A (various lengths offered)
25GBASE-SR multimode fiber 1500 MHz*km
3500 MHz*km
2 - 70 meters
2 - 100 meters
25GBASE-eSR multimode fiber 1500 MHz*km
3500 MHz*km
2 - 200 meters
2 - 400 meters
25GBASE-LR single mode fiber N/A 2 - 10,000 meters
40GBASE-CR4 twinaxial copper N/A (various lengths offered)
40GBASE-SR4 multimode fiber 1500 MHz*km
3500 MHz*km
2 - 100 meters
2 - 150 meters
40GBASE-eSR4 multimode fiber 1500 MHz*km
3500 MHz*km
2 - 330 meters
2 - 550 meters
40GBASE-LR4 single mode fiber N/A 2 - 10,000 meters
40GBASE-ER4 single mode fiber N/A
2 - 40,000 meters
2
40GBASE-BiDi multimode fiber 1500 MHz*km
3500 MHz*km
2 - 100 meters
2 - 150 meters
100GBASE-CR4 twinaxial copper N/A (various lengths offered)
100GBASE-SR4 multimode fiber 1500 MHz*km
3500 MHz*km
2 - 100 meters
2 - 150 meters
100GBASE-LR4 single mode fiber N/A 2 - 10,000 meters
1
Refer to Table 6, footnote 3, for ports that support 10GBase-T transceivers.
2
The JL563A 10GBase-T transceiver is limited to a 30m cable length.
3
For distances less than 20km, a 10dB attenuator must be used. For distances between 20km and 40km, a
5dB attenuator must be used. Attenuators can be purchased from most cable vendors.
Table 41: Technology distance specifications (Continued)
Technology Supported cable type Multimode fiber
modal bandwidth
Supported distances