Samples type : delta
Variable formula : 1.3.6.1.2.1.16.1.1.1.4.1<etherStatsOctets.1>
Sampling interval : 5(sec)
Rising threshold : 100(linked with event 1)
Falling threshold : 50(linked with event 2)
When startup enables : risingOrFallingAlarm
Latest value : 0
# Display statistics for interface Ethernet 1/0/1.
<Sysname> display rmon statistics Ethernet 1/0/1
EtherStatsEntry 1 owned by user1-rmon is VALID.
Interface : Ethernet1/0/1<ifIndex.3>
etherStatsOctets : 57329 , etherStatsPkts : 455
etherStatsBroadcastPkts : 53 , etherStatsMulticastPkts : 353
etherStatsUndersizePkts : 0 , etherStatsOversizePkts : 0
etherStatsFragments : 0 , etherStatsJabbers : 0
etherStatsCRCAlignErrors : 0 , etherStatsCollisions : 0
etherStatsDropEvents (insufficient resources): 0
Packets received according to length:
64 : 7 , 65-127 : 413 , 128-255 : 35
256-511: 0 , 512-1023: 0 , 1024-1518: 0
After completing the configuration, you may query alarm events on the NMS. On the monitored device,
alarm event messages are displayed when events occur. The following is a sample output:
[Sysname]
#Aug 27 16:31:34:12 2005 Sysname RMON/2/ALARMFALL:Trap 1.3.6.1.2.1.16.0.2 Alarm table 1
monitors 1.3.6.1.2.1.16.1.1.1.4.1 with sample type 2,has sampled alarm value 0 less than(or
=) 50.
104

Table of Contents

Other manuals for HP JD320B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP JD320B and is the answer not in the manual?

HP JD320B Specifications

General IconGeneral
BrandHP
ModelJD320B
CategorySwitch
LanguageEnglish

Related product manuals