5-7
RADIUS Authentication and Accounting
Configuring the Switch for RADIUS Authentication
Outline of the Steps for Configuring RADIUS
Authentication
There are three main steps to configuring RADIUS authentication:
1. Configure RADIUS authentication for controlling access through one or
more of the following
Serial port
•Telnet
•SSH
Web browser interface
Port-Access (802.1X)
2. Configure the switch for accessing one or more RADIUS servers (one
primary server and up to two backup servers):
Note This step assumes you have already configured the RADIUS server(s) to
support the switch. Refer to the documentation provided with the
RADIUS server documentation.)
Server IP address
(Optional) UDP destination port for authentication requests (default:
1812; recommended)
(Optional) UDP destination port for accounting requests (default:
1813; recommended)
(Optional) encryption key for use during authentication sessions with
a RADIUS server. This key overrides the global encryption key you
can also configure on the switch, and must match the encryption key
used on the specified RADIUS server. (Default: null)
3. Configure the global RADIUS parameters.
Server Key: This key must match the encryption key used on the
RADIUS servers the switch contacts for authentication and account-
ing services unless you configure one or more per-server keys.
(Default: null.)
Timeout Period: The timeout period the switch waits for a RADIUS
server to reply. (Default: 5 seconds; range: 1 to 15 seconds.)
Retransmit Attempts: The number of retries when there is no server
response to a RADIUS authentication request. (Default: 3; range of 1
to 5.)
Server Dead-Time: The period during which the switch will not send
new authentication requests to a RADIUS server that has failed to
respond to a previous request. This avoids a wait for a request to time

Table of Contents

Other manuals for HP ProCurve 2810 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2810 Series and is the answer not in the manual?

HP ProCurve 2810 Series Specifications

General IconGeneral
Jumbo Frame SupportYes
ModelHP ProCurve 2810 Series
Ports24 or 48 10/100/1000 ports
Uplink Ports4 SFP (mini-GBIC) slots
Forwarding Rate71.4 Mpps
LayerLayer 2
ManagementWeb, SNMP, CLI
MAC Address Table Size16000 entries
Routing ProtocolStatic IP routing
Form FactorRack-mountable
Power Consumption48W (24-port)
Operating Temperature32°F to 0°F (0°C to 0°C)
Operating Humidity15% to 95% non-condensing
Power SupplyInternal power supply

Related product manuals