A-1
Specifications
A
Specifications
Physical
Electrical
The switch automatically adjusts to any voltage between 100-127 and 200-240
volts and either 50 or 60 Hz.
Environmental
3500yl-24G (J8692A) and
6200yl-24G(J8992A)
3500yl-48G (J8693A)
Width: 44.3 cm (17.42 in) 44.3 cm (17.42 in)
Depth: 39.2 cm (15.43 in) 43.0 cm (16.9 in)
Height: 4.4 cm (1.7 in) 4.4 cm (1.7 in)
Weight: 6.4 kg (14.10 lbs) 7.3 kg (16.1 lbs)
3500yl-24G-PWR
(J8692A)
6200yl-24G
(J8992A)
3500yl-48G-PWR
(J8693A)
AC voltage: 100-127/200-240 volts 100-127/200-240 volts 100-127/200-240 volts
Maximum current: 10.0A/5.0A 4.0A/2.0A 10.0A/5.0A
Frequency range: 50/60 Hz 50/60 Hz 50/60 Hz
Operating Non-Operating
Temperature: 0°C to 55°C (32°F to 131°F)
1
-40°C to 70°C (-40°F to 158°F)
Relative humidity:
(non-condensing)
15% to 95% at 40°C (104°F) 15% to 90% at 65°C (149°F)
Maximum altitude: 4.6 km (15,000 ft) 4.6 km (15,000 ft)
1
If you are installing either the Series 3500yl or 6200yl Switches using any of the X2
transceivers, the operating ambient temperature should not exceed 40°C (104°F).
See transceiver specifications.