Hardware options installation 51
FBWC capacitor pack
To install the component:
CAUTION: The cache module connector does not use the industry standard DDR3 mini DIMM
pinout. Do not use this controller with cache modules designed for other controller models,
because the controller can malfunction and you can lose data. Also, do not transfer this cache
module to an unsupported controller model, because you can lose data.
1. Back up all data.
2. Close all applications.
3. If installed, remove the rack bezel (on page 59).
4. Power down the server (on page 17).
CAUTION: In systems that use external data storage, be sure that the server is the first unit to be
powered down and the last to be powered back up. Taking this precaution ensures that the system
does not erroneously mark the drives as failed when the server is powered up.
5. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
6. Extend the server from the rack (on page 17).
7. Remove the access panel (on page 19).
8. Remove the processor air baffle (on page 19).
9. Remove the PCI riser cage (on page 20).
10. Install the FBWC capacitor pack into the FBWC module.
11. Install the FBWC module into the server.
o Eight-drive SFF