Hardware options installation 64
CAUTION:
Any attempt to remove an installed TPM from the system board breaks or disfigures
the TPM security rivet. Upon locating a broken or disfigured rivet on an installed TPM,
administrators should consider the system compromised and take appropriate measures to ensure
the integrity of the system data.
8. Install the TPM board. Press down on the connector to seat the board ("System board components" on
page 11).
9. Install the TPM security rivet by pressing the rivet firmly into the system board.
10. Install the PCI riser cage.
11. Install the processor air baffle (on page 20).
12. Install the access panel (on page 19).
13. Slide the server into the rack.
14. Connect each power cord to the server.
15. Connect each power cord to the power source.
16. Power up the server (on page 17).
17. If removed, install the rack bezel (on page 60).