Diagnostic tools and Setup Utilities 90
Table 11 POST Error Messages
Error-Code Error Message Description / Corrective Action
04D Primary Master Hard Disk
Error
The IDE/ATAPI device configured as Primary Master could not be
properly initialized by the BIOS.This message is typically displayed
when the BIOS is trying to detect and configure IDE/ATAPI devices
in POST
04E Primary Slave Hard Disk
Error
The IDE/ATAPI device configured as Primary Slave could not be
properly initialized by the BIOS. This message is typically
displayed when the BIOS is trying to detect and configure
IDE/ATAPI devices in POST.
04F Secondary Master Hard
Disk Error
The IDE/ATAPI device configured as Secondary Master could not
be properly initialized by the BIOS. This message is typically
displayed when the BIOS is trying to detect and configure
IDE/ATAPI devices in POST.
050 Secondary Slave Hard Disk
Error
The IDE/ATAPI device configured as Secondary Slave could not be
properly initialized by the BIOS. This message is typically
displayed when the BIOS is trying to detect and configure
IDE/ATAPI devices in POST.
051 Master Hard Disk Error The IDE/ATAPI device configured as Master in the 3rd IDE
controller could not be properly initialized by the BIOS. This
message is typically displayed when the BIOS is trying to detect
and configure IDE/ATAPI devices in POST.
052 Master Slave Disk Error The IDE/ATAPI device configured as Slave in the 3rd IDE controller
could not be properly initialized by the BIOS. This message is
typically displayed When the BIOS is trying to detect and
configure IDE/ATAPI devices in POST.
604 System Fan not installed System fan is not installed, user should install the system fan.
603 CPU Fan not installed CPU fan is not installed, user should install the CPU fan. This could
cause thermal issues with the CPU.
601 BMC Not Responding BMC not responding, you can load the optimal default value, or
you must change the LO100 card.
POST Related Troubleshooting
Perform the following procedures when POST fails to run, displays error messages, or emits beep
codes.
If the POST failure is during a routine boot up, check the following:
All external cables and power cables should be firmly plugged in.
The power outlet to the server should be connected and works correctly.
The server and monitor are both turned on. The bicolour status LED indicator on the front panel
must be lit up green.
The monitor's contrast and brightness settings are correct.
All internal cables are properly connected and all boards firmly seated.
The processor is fully seated in its socket on the system board.