Physical and Operating Specifications 94
Table 14 Environmental Specifications
Item Description
Thermal output (maximum operating)
Acoustic emissions
Normal configuration
392 W/hr
LWad: 6.7 Bels
(operating at room temperature)
LWad: 6.7 Bels
(Idle at room temperature)
Table 15 Power Supply Specifications
Item Description
Dimensions (H x W x D) 38.5 mm x 86.4 mm x 190.5 mm
Weight (approximate)
1.0 kg
Input requirements:
Rated input voltage
Normal line voltage
90 VAC to 264 VAC
100 VAC to 120 VAC /200 VAC to 240 VAC
Line frequency 47 ā 63 Hz
Rated input current 9.10 A rms max @ 100V
BTU rating N/A
Power supply output power:
Rated steady state power
Maximum peak power
750W (1+1 Redundant)
N/A
Temperature range:
Operating
Shipping
+5C to +50C
ā40C to +85C
Relative humidity:
Operating
Non-operating
5% to 95% relative humidity, non-condensing.
5% to 95% relative humidity, non-condensing