Removal and replacement procedures 58
a.
Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 29).
o Remove the server from the rack (on page 30).
4. Remove the access panel ("Access panel" on page 35).
5. Remove the air baffle ("Air baffle" on page 35).
WARNING: To reduce the risk of personal injury from hot surfaces, allow the power supply or
power supply blank to cool before touching it.
6. Remove the non-hot-plug power supply ("Non-hot-plug power supply" on page 57).
7. If installed, remove the dedicated iLO management port module.
8. Remove the non-hot-plug power supply bracket.
To replace the component, reverse the removal procedure.
RPS enablement kit
WARNING: To reduce the risk of personal injury from hot surfaces, allow the power supply or
power supply blank to cool before touching it.
To remove the component:
1. Power down the server (on page 28).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 29).