Hardware options installation 47
5.
Install the fan module into the fan bay.
6. Install the access panel (on page 20).
7. Slide the server back into the rack.
8. If the fan installation was made to upgrade the server from a nonredundant to a redundant fan mode,
reboot the server.
Installing a hot-plug fan module if the server is installed in a friction
rail system
1. Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes
from amber to green.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Remove the server from the rack (on page 18).
4. Remove the access panel (on page 19).
5. Do one of the following: