Specifications 96
CAUTION: Check the system and power supply input ratings before powering up the server.
HP 460 W CS Gold Hot-plug Power Supply (92% efficiency)
Specification Value
Input requirements
Rated input voltage
100 V AC to 240 V AC
Rated input frequency
50 Hz or 60 Hz
Rated input current
6 A to 3 A
Rated input power
526 W at 100 V AC input
505 W at 200 V AC input
BTU per hour
1794 at 100 V AC input
1725 at 200 V AC input
Power supply output
Rated steady-state power
460 W at 100 V to 120 V AC
input
460 W at 200 V to 240 V AC
input
Maximum peak power
460 W at 100 V to 120 V AC
input
460 W at 200 V to 240 V AC
input
HP 460 W CS Platinum Plus Hot-plug Power Supply (94%
efficiency)
Specification Value
Input requirements
Rated input voltage
100 V AC to 240 V AC
Rated input frequency
50 Hz or 60 Hz
Rated input current
6 A to 3 A
Rated input power
509 W at 115 V AC input
495 W at 230 V AC input
BTU per hour
1764 at 100 V AC input
1736 at 115 V AC input
1694 at 200 V AC input
1687 at 230 V AC input
Power supply output
Rated steady-state power
460 W at 100 V to 120 V AC input
460 W at 200 V to 240 V AC input
Maximum peak power
460 W at 100 V to 120 V AC input
460 W at 200 V to 240 V AC input