Hardware options installation 59
Redundant hot-plug power supply option
CAUTION:
All power supplies installed in the server must have the same output power capacity.
Verify that all power supplies have the same part number and label color. The system becomes
unstable and may shut down when it detects mismatched power supplies.
Label color Output
Blue
460W
Orange
750W
White
750W 48V DC
Green
1,200W
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
To install the component:
1. Unfasten the cable management solution to access the power supply bays.
2. Remove the power supply blank.