Troubleshooting
HP ProLiant DL585 Server User Guide H-9
Table H-5: Is the internal health LED green?
Answer Possible reasons Possible solutions
For component failure identification (amber LED), check the hood label.
No, it is
amber.
A processor is in a pre-failure
condition.
A DIMM is in a pre-failure
condition.
One memory bank is valid, but
another bank is missing a DIMM.
One memory bank is valid, but
another bank has mismatched
DIMMs installed.
One memory bank is valid, but
another bank has an
unsupported DIMM type installed.
A redundant fan has failed.
Use internal component failure LEDs on the
Quickfind Diagnostic Display to identify:
Missing components
Degraded components
Failed components
Improperly installed components
For corrective procedures, refer to the
maintenance and service guide on the
Documentation CD that ships with the
server.
Contact an authorized service provider for
replacement parts and service.
continued