Removal and replacement procedures 62
7.
Remove the FlexibleLOM riser board.
To replace the component, reverse the removal procedure.
System battery
If the server no longer automatically displays the correct date and time, then replace the battery that
provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.
WARNING: The computer contains an internal lithium manganese dioxide, a vanadium
pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:
Do not attempt to recharge the battery.
Do not expose the battery to temperatures higher than 60°C (140°F).
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
Replace only with the spare designated for this product.
To remove the component:
1. Power down the server (on page 27).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
o Extend the server from the rack (on page 27).
o Remove the server from the rack (on page 30).
4. Remove the access panel ("Access panel" on page 35).
5. Locate the battery on the system board ("System board components" on page 97).
WARNING:
Do not exert too much force to remove the system battery. The battery could pop
out of the socket, or the tool could slip and damage the socket or the system board.