164 Maintaining the switch configuration file
Example: Configuration file
[Configuration upload Information]
Configuration Format = 2.0
date = Thu Oct 9 21:22:25 2008
FOS version = v6.2.0.0
Number of LS = 2
[Chassis Configuration Begin]
[fcRouting]
[Chassis Configuration]
[LicensesDB]
[DMM_WWN]
[Licenses]
[Chassis Configuration End]
date = Thu Oct 9 21:22:25 2008
[Switch Configuration Begin : 0]
SwitchName = n200
Fabric ID = 128
[Boot Parameters]
[Configuration]
[Zoning]
[Defined Security policies]
[Active Security policies]
[iSCSI]
[cryptoDev]
[FICU SAVED FILES]
[Banner]
[End]
[Switch Configuration End : 0]
date = Thu Oct 9 21:22:25 2008
[Switch Configuration Begin : 1]
SwitchName = n200
Fabric ID = 100
[Boot Parameters]
[Configuration]
[Zoning]
[Defined Security policies]
[Active Security policies]
[iSCSI]
[cryptoDev]
[FICU SAVED FILES]
[Banner]
[End]
[Switch Configuration End : 1]
Chassis section
There is only one chassis section within a configuration. It defines configuration data for chassis
components that affects the entire system—not just an individual Logical Switch. The chassis section is
included in non-Virtual Fabric modes only if you use the configUpload
-all command. The following
software components are defined in the chassis area:
• fcRouting
• chassis configuration
• licensesDB
• DMM_WWN
• licenses

Table of Contents

Other manuals for HP StorageWorks 4/8 - SAN Switch

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks 4/8 - SAN Switch and is the answer not in the manual?

HP StorageWorks 4/8 - SAN Switch Specifications

General IconGeneral
BrandHP
ModelStorageWorks 4/8 - SAN Switch
CategorySwitch
LanguageEnglish

Related product manuals