Action(s)Error Message and DescriptionError Code
System action: Proceeds to the next
definition statement (Termination code 08).
User action: Check that the value for CODE
matches the type of conversion, and then
re-execute.
CODE statement is wrong value. Operation
is executed with CODE=code.
Wrong value is specified for CODE
statement.
CCNV10F-I
System action: Proceeds to the next
definition statement (Termination code 08).
User action: Re-execute after checking the
following for the code to be customized:
• A shift code is not specified for the
code to be customized.
Size of code (code) to customize is wrong.
Wrong code specified for the code to be
customized.
CCNV10G-I
System action: Operation continues
(Termination code 12).
Failed to generate code conversion table.
Failed to generate code conversion table
due to an unspecified error.
CCNV10H-I
System action: Operation continues with
the first NAME statement as the valid
NAME statement (Termination code 08).
User action: Check the NAME statement
and re-execute with only the desired NAME
statement specified.
Cannot specify more than one NAME
statement.
More than one NAME statement is
specified.
CCNV10I-I
System action: Operation continues
(Termination code 00).
Code conversion table successfully
generated.
A code conversion table was created with
the specified name.
CCNV102-I
System action: Proceeds to the next
definition statement (Termination code 12).
User action: Re-execute after reviewing the
contents of the preceding message and
making the necessary corrections.
Cannot generate code conversion table
due to error.
Failed to create code conversion table due
to reasons indicated by the preceding error
message.
CCNV103-I
System action: Terminates operation
(Termination code 12).
User action: Specify the definition
statements and re-execute.
Definition statement not specified.
Cannot execute utility because there is no
definition statement specified.
CCNV104-I
System action: Terminates operation
(Termination code 12).
User action: Re-execute after checking the
following:
• The table name is specified in 255 or
fewer alphanumeric characters begin-
ning with an alphabetic character.
• NAME is specified.
NAME statement is wrong value or not
specified.
CCNV105-I
Troubleshooting80

Table of Contents

Other manuals for HP StorageWorks P9000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 and is the answer not in the manual?

HP StorageWorks P9000 Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000
CategoryStorage
LanguageEnglish

Related product manuals