Page #86 background imageLoading...
Page #86 background image
ActionMeaningError messageError Code
Select Error from the Help
menu to view the system
error code, and then check
the operating system
document for error details.
Cannot allocate memory for
UOC output interface/pipe
output interface logging.
Output log buffer :
Allocation error
-617
Confirm the FCU
configuration is correct.
Null pointer passed from
FCU.
Null pointer (fcuuocRCedit)
error
-640
Select Error from the Help
menu to view the system
error code, and then check
the operating system
document for error details.
Cannot open the Field
Definition file.
Field definition file open
error
-641
Select Error from the Help
menu to view the system
error code, and then check
the operating system
document for error details.
Cannot open the Edit
Option file.
Edit option file open error-642
Select Error from the Help
menu to view the system
error code, and then check
the operating system
document for error details.
Cannot read the Field
Definition file.
Field definition file read
error
-643
Select Error from the Help
menu to view the system
error code, and then check
the operating system
document for error details.
Cannot read the Edit
Option file.
Edit option file read error-644
Check the Field Definition
file.
The Field Definition file
parameter specifies a first
byte position or a field
length that goes beyond the
edit source buffer length.
Field definition file : Top
point/field length over flow
error
-645
Check the Field Definition
file.
Output field length is larger
than the maximum record
length (32KB).
Field definition file :
Output field size over flow
-646
Check the Field Definition
file.
The total size of the edited
record is 0 byte.
Edited size error-647
Select Error from the Help
menu to view the system
error code, and then check
the operating system
document for error details.
Cannot allocate memory for
tracing.
Memory allocate error-648
Check the dataset settings
and installation of
FAL/FCU.
The length of the dataset is
not fixed.
Record format error-649
Troubleshooting86

Table of Contents

Other manuals for HP StorageWorks P9000