What does path rejected mean on HP StorageWorks P9000?
- RreedmarcSep 14, 2025
If you encounter a 'Path Rejected' error (MCU/RCU) on your HP Storage, start by deleting the failed path. Additionally, delete all paths and secondary systems that are not currently in use. Remember that the primary system can connect to a maximum of four secondary systems, with up to eight paths to each system. Ensure that all primary and secondary system ports are properly configured: use ordinary RCU target ports for secondary systems and initiator ports for primary systems. If necessary, connect to the secondary system to delete paths, reconfigure the ports, then reconnect to the primary system and add the path or secondary system again using Edit Path or Add RCU.