EasyManua.ls Logo

HP StorageWorks P9000 - User Manual

HP StorageWorks P9000
322 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
HP StorageWorks
P9000 Data Exchange Code Converter User
Guide
Abstract
This guide describes and provides instructions for installing and using the Data Exchange feature of the HP XP
P9000 storage systems.
Part Number: T1620-96017
First edition: October 2010

Table of Contents

Other manuals for HP StorageWorks P9000

Questions and Answers

  • D
    duncanjohnSep 9, 2025
    What does 'Port number invalid' mean on HP StorageWorks P9000 Storage?
    • J
      johnny55Sep 9, 2025
      If you receive a 'Port number invalid' error, it means that the specified port number is invalid or the cable is not connected to the specified port. Delete the failed path. Check the specified port number or the cable connection and then retry.
  • A
    Andrea ArnoldSep 9, 2025
    What does 'PSUE, by RCU' mean in HP StorageWorks P9000 Storage?
    • A
      andersonbrandonSep 9, 2025
      The 'PSUE, by RCU' message indicates that the primary storage system suspended a pair because it detected an error condition at the secondary storage system. Clear the error condition at the secondary storage system or S-VOL. If you need to access the S-VOL, release the pair from the primary storage system. If data in the S-VOL has been changed, release the pair from the primary storage system and then recreate the pair using the Paircreate dialog box. If data in the S-VOL has not been changed, restore the pair from the primary storage system.
  • X
    xzunigaSep 9, 2025
    What does 'PSUE, S-VOL Failure' mean for HP StorageWorks P9000?
    • B
      Brittney BrownSep 10, 2025
      The message 'PSUE, S-VOL Failure' means the primary storage system detected an error during communication with the secondary storage system or detected an I/O error during update copy. Clear any error conditions at the secondary storage system and the S-VOL. If you need to access the S-VOL, release the pair from the secondary storage system. If data in the S-VOL has been changed, release the pair from the primary storage system and then recreate the pair by using the Paircreate dialog box. If data in the S-VOL has not been changed, restore the pair from the primary storage system.
  • K
    Kenneth Carey IISep 10, 2025
    What to do if HP Storage reports 'Program Error'?
    • H
      hpalmerSep 10, 2025
      If a 'Program Error' is detected, delete the path by using the Delete Path or Delete DKC command, and then add the path and the secondary system again by using the Add Path or Add DKC command.
  • S
    Stephen RodgersSep 10, 2025
    How to resolve 'Communication error' on HP StorageWorks P9000?
    • K
      Kimberly CastilloSep 12, 2025
      If a 'Communication error' occurs, which means a timeout error happened in the path between the primary and secondary systems, delete the failed path and retry.
  • J
    jamesbrownSep 12, 2025
    What does 'This path was not established' mean on HP Storage?
    • K
      Karen LynchSep 12, 2025
      If you see the message 'This path was not established', delete the failed path. You may need to change the minimum paths setting or delete the secondary system in order to delete the path. After deletion finishes, add the path and the secondary system by using the Add Path or Add DKC command.
  • C
    cmeadowsSep 12, 2025
    How does a planned power outage affect HP StorageWorks P9000 Storage?
    • B
      Brandon ColemanSep 12, 2025
      If Cnt Ac-J pairs were temporarily suspended due to a planned power outage to the primary system, no recovery procedure is required. The primary system automatically removes the suspension condition when the system is powered on.
  • T
    thomashardinSep 12, 2025
    What does 'PSUE, MCU IMPL' mean for HP Storage?
    • J
      jennifer44Sep 12, 2025
      The error 'PSUE, MCU IMPL' indicates that the primary storage system couldn't find valid control information in its nonvolatile memory during the IMPL procedure. Restore the pair (pairresync) from the primary storage system. The primary storage system performs an initial copy operation in response to the pairresync request, so that the entire P-VOL is copied to the S-VOL.
  • G
    gabrielanunezSep 12, 2025
    What does 'PSUE, Initial Copy Failed' mean on HP Storage?
    • J
      John HuffmanSep 12, 2025
      If you encounter 'PSUE, Initial Copy Failed', it means the primary storage system suspended this pair during the initial copy operation. Release the pair from the primary storage system. Clear all error conditions at the primary storage system, P-VOL, secondary storage system, and S-VOL. Restart the initial copy operation by using the Paircreate dialog box.
  • D
    Dawn TuckerSep 12, 2025
    What to do if HP StorageWorks P9000 Storage displays 'In Progress'?
    • D
      Daniel KellySep 12, 2025
      If the status is 'In Progress', it indicates that the processing of the attribute modifying is in progress. Wait until the processing terminating.

Summary

1 Overview of HP StorageWorks Data Exchange Software Code Converter

Overview of Code Converter

General introduction to the Data Exchange Code Converter functionality and its purpose.

Data Exchange Code Converter Process

Describes the operational flow and components involved in the Data Exchange Code Converter.

2 Code Converter Functions

Alphanumeric Character Conversion Function

Details the process of converting alphanumeric character data, focusing on single-byte codes.

Double-byte Character Conversion Function

Explains double-byte character conversion, including mixed single and double-byte data.

Numeric Conversion Function

Covers the conversion of numeric data fields, including process flow.

3 System Requirements and Installation

System Requirements

Lists the necessary hardware, software, and release notes for the Code Converter.

Installation Media for UNIX-based Systems

Details the files and their locations provided on the installation media for UNIX.

Installing and Uninstalling for UNIX Systems

Step-by-step guide for installing, uninstalling, and upgrading on UNIX systems.

License Key Input

Explains how to input the license key required for Code Converter operation.

4 Using Data Exchange Code Converter

Data Exchange Code Converter User Process Flow

Illustrates the user's workflow for performing data conversion operations.

Database Data File Record Format

Describes the supported record formats and field positions for data files.

5 Mainframe to Open System (MTO) Character Code Conversion

Overview of Character Code Conversion

Introduces MTO conversion, including EBCDIC to ASCII and IBM Traditional Chinese to Big5.

Alphanumeric Field Conversion (CHAR:OPK4)

Details the specific conversion of alphanumeric fields in MTO.

6 Open System to Mainframe (OTM) Character Code Conversion

Overview

Introduces OTM conversion, including ASCII to EBCDIC and Big5 to IBM Traditional Chinese.

Customizing the Code Conversion Table

Explains how to customize the code conversion table for OTM.

7 Numeric Conversion

Packed Decimal Conversion (NUM:OPA1)

Details the conversion of packed decimal numeric data.

Zoned Decimal Conversion (NUM:OPA2)

Explains the process for converting zoned decimal numeric data.

8 Customizing the Code Conversion Table

Operation Overview

Provides a high-level overview of the code conversion table customization process.

Definition Statement Syntax

Describes the syntax rules for defining conversion statements used in customization.

Command Syntax for UNIX Systems

Explains the command syntax for customizing tables on UNIX systems.

9 Troubleshooting

Error Codes

Lists and explains common error codes and their meanings.

ccnv Messages

Details the format and interpretation of messages generated by the ccnv utility.

Calling HP Technical Support

Provides guidance on what information to gather before contacting HP support.

10 Support and Other Resources

Related Documentation

Lists other relevant HP documents for further information.

HP Technical Support

Information on how to obtain technical support from HP.

A Edit Option File

B HOSTBIG5

C EBCDIC-ASCII Code Conversion

Glossary

HP StorageWorks P9000 Specifications

General IconGeneral
RAID SupportRAID 0, 1, 5, 6, 10
InterfaceFibre Channel, iSCSI, FCoE
Form FactorRack-mountable
ModelP9000
Operating System CompatibilityWindows, Linux, VMware, HP-UX
Host InterfaceFibre Channel, iSCSI, FCoE
Drive InterfaceSAS, SSD
Drive Types SupportedSSD, SAS
RedundancyRedundant controllers, power supplies, and fans
Management SoftwareHP StorageWorks Command View

Related product manuals