36
MaxTotalMembers—The maximum number of zone and alias members that can be stored in the
switch’s zoning database. Each instance of a zone member or alias member counts toward this
maximum.
MaxZonesInZoneSets—The maximum number of zone linkages to zone sets that can be configured on
the switch. A linkage is configured every time a zone is added to a zone set.
MaxMembersPerZone—The maximum number of zone members that can be added to any zone on the
switch. When added to a zone, an alias is considered to be a zone member.
MaxMembersPerAlias—The maximum number of zone members that can be added to any alias on the
switch.
To view zoning properties and limits on a switch:
1. On the faceplate display, select Zoning > Edit Zoning to open the Edit Zoning dialog box.
2. Choose one of the following options:
View the zoning properties/limits located directly below the zoning tool bar (Figure 18).
In the zone sets tree (left pane), right-click the Zone Sets entry at the top of the tree, and then select
Properties.
In the zone sets tree (left windowpane), select the zone sets entry at the top of the tree, and then
select Edit > Properties from the menu bar.
3. When you have finished viewing the zoning properties information, click OK to close the Properties
dialog box.
Managing the zoning database
The zoning database is managed using the following options:
Editing the zoning database, page 36
Options for resolving zoning, page 39
Configuring the zoning database, page 39
Saving and restoring the zoning database to a file, page 40
Restoring the zoning database from a file, page 40
Restoring the default zoning database, page 40
Removing all zone and zone set definitions, page 41
Editing the zoning database
Use the Edit Zoning dialog box (Figure 18) to edit the zoning database of a particular switch or stack. To
open the Edit Zoning dialog box:
1. Select a switch or a stack in the fabric tree.
2. Select Zoning > Edit Zoning.
3. If you selected a stack and the zoning database is not identical on all switches in the stack, choose a
switch from the Select Source Switch list. Changes that you make to this switch are distributed to the
other switches in the stack.
4. Click OK.

Table of Contents

Other manuals for HP StorageWorks SN6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks SN6000 and is the answer not in the manual?

HP StorageWorks SN6000 Specifications

General IconGeneral
BrandHP
ModelStorageWorks SN6000
CategorySwitch
LanguageEnglish

Related product manuals