Electrostatic Discharge
50 1U Rackmount Tape Enclosure Reference Guide
 Grounding methods
There are several methods for grounding. Use one or more of the following 
methods when handling or installing electrostatic-sensitive parts:
■ Use a wrist strap connected by a ground cord to a grounded workstation or 
computer chassis. Wrist straps are flexible straps with a minimum of 1 
megohm ± 10 percent resistance in the ground cords. To provide proper 
grounding, wear the strap snug against the skin.
■ Use heel straps, toe straps, or boot straps at standing workstations. Wear the 
straps on both feet when standing on conductive floors or dissipating floor 
mats.
■ Use conductive field service tools. 
■ Use a portable field service kit with a folding static-dissipating work mat.
If you do not have any of the suggested equipment for proper grounding, have an 
authorized reseller install the part.
Note:  For more information on static electricity, or for assistance with product 
installation, contact your authorized reseller.