4. Install the enclosure into the rack.
CAUTION: Use extreme caution when installing and pulling units from the rack. Unattached units
can slip and fall, damaging the StoreOnce System or causing personal injury. Hewlett Packard
Enterprise is not responsible for any damage or injury caused by mishandling the StoreOnce
system.
Always use at least two people to lift and locate an enclosure into the rack.
a. Verify that the storage enclosure has the correct JBOD number.
The storage enclosure has a pull-out tab in the upper left corner of the rear panel. The tab shows
the JBOD number. In a system with multiple enclosures, having the correct JBOD numbers on each
pull-out tab will ease any necessary troubleshooting procedures.
If the enclosure was part of the initial order, the JBOD number is preinstalled on the pull-out tab.
If the enclosure was not part of the initial order, apply the JBOD number from the sheet of
stickers to the pull-out tab.
b. Slide the enclosures into position on the rails (1). Secure the chassis into the rack by tightening the
captive CTO screw behind the latch on the front left and right bezel ears of the chassis (2).
CAUTION: The front CTO screw must be attached at all times when racked.
When installing two storage enclosures, slide the lowest enclosure, JBOD 2, into position first.
30 HPE StoreOnce 3640 System