a. Connect a 0.5 m SAS cable from the RAID controller on the server node to port 1 on the capacity
upgrade enclosure (JBOD 1).
If the cable is not already labeled, apply the labels before installing the cable.
SAS cable Label color Label
New 0.5 m cable Red N:S6:P1 - J1:I1:P1
Item Description
1 Server node.
2 JBOD 1: First capacity upgrade kit.
3 0.5 m SAS cable.
b. If the system includes a second capacity upgrade enclosure, connect a 0.5 m SAS cable from port
2 on the first capacity upgrade enclosure (JBOD 1) to port 1 on the second capacity upgrade
enclosure (JBOD 2).
If the cable is not already labeled, apply the labels before installing the cable.
SAS cable Label color Label
New 0.5 m SAS cable Red J1:I1:P2 - J2:I1:P1
Figure 12: Cabling the second capacity upgrade enclosure