C. SOLAR HEAT EXCHANGER PIPING
Figure 5 - This drawing is meant to demonstrate system piping concept only.
Set up the primary balance of the system components following the piping detail in Figure 5.
Run ½” type M or larger copper pipes, or flex line sets, to and from the collector following the direction of
supports, penetrations, and other relative items.
Only copper, cast iron, or brass are to be allowed in the collector piping loop due to transient operating
temperatures that may reach as high as 300
o
F. PEX, PVC, CPVC, and other polymers are expressly
prohibited in the piping network.