15
downward to allow complete drainage. The end of the discharge piping should not be threaded or
concealed and must be protected from freezing. No valve of any type, restriction or reducer coupling
should be installed in the discharge line.
Mixing Valve (Rated ASSE 1017)
Automatically blends the hot and cold water feed lines to control discharge to an acceptable and safe
temperature. This also increases the amount of hot water that is drawn from the solar water heater by not
allowing the incoming water to fully temper the hot water stored inside the tank.
Ball Valve (for cold water shut-off) (Valve #24)
The cold water shut off valve should be used in the event of an emergency shutdown.
It is very important that you do the potable piping before you pipe into the solar system. Failure to do so
may damage your water heater.