LP-454 Rev. 004 Rel. 002 Date 12.1.17
12
E
AIR INLET
EXHAUST
F
PORT SIZES
MODEL
COLD WATER
INLET
HOT WATER
OUTLET
AUXILIARY VENTING GAS LINE CONDENSATE
PHP199-119
1-1/2" MNPT
3.81 cm
1-1/2" FNPT
3.81 cm
1" MNPT
2.54 cm
3"
7.62 cm
3/4" FNPT
1.905 cm
3/4" MNPT
1.905 cm
4"
10.16 cm
PHP260-119
PHP320-119
PHP399-119
LP-454-K
10/27/14
MODEL A B C D E F G H J
SHIPPING
WEIGHT
LBS/KG
PHP199-119
11-3/16"
28.42 cm
5-1/2"
13.97cm
7"
17.78cm
42-1/8"
107 cm
32"
81.28 cm
77"
195.58 cm
16"
40.64 cm
9-3/4"
24.76 cm
49"
124.46 cm
475
215.46 kg
85"
215.9 cm
58-3/4"
149.22 cm
555
251.74 kg
PHP260-119
PHP320-119
575
260.82 kg
PHP399-119
GAS
CONNECTION
CONDENSATE
LINE
D
B
C
A
OUTLET
HOT WATER
AUXILIARY
COLD WATER
INLET
J
H
G
Figure 4 - Water Heater Dimensions - NOTE: All Dimensions Are Approximate
Performance Specications for Phoenix Plus Models
BTU/Hr Eciency
Temperature Rise in Degrees Fahrenheit (F) and Celsius (C)
(°F) 40 50 60 70 80 90 100 110 120 130 140
(°C) 22 28 33 39 44 50 56 61 67 72 78
199,000
95%
GPH 579 463 386 331 289 257 232 211 193 178 165
LPH 2192 1753 1461 1253 1094 973 878 799 731 673 625
260,000
GPH 756 605 504 432 378 336 303 275 252 233 216
LPH 2862 2290 1908 1653 1431 1272 1147 1041 954 882 818
320,000
GPH 931 745 621 532 465 414 372 339 310 286 266
LPH 3524 2820 2351 2014 1760 1567 1408 1283 1174 1083 1007
399,000
GPH 1161 929 774 663 580 516 464 422 387 357 332
LPH 4395 3517 2930 2510 2196 1953 1756 1597 1465 1351 1257
Table 3 - 95% Thermal Eciency Used for Calculations
Performance Equations
Rated Input x .95
GPM = Temp Rise (
o
F) x 500 GPH = GPM x 60