LP-454 Rev. 004 Rel. 002 Date 12.1.17
20
accidental contact with people or pets, or damage air conditioners,
shrubs, or other plants or objects.
12. DO NOT vent the water heater in a chimney ue serving a separate
appliance designed to burn solid fuel. The water heater may only be
vented in vacant chimneys. In vacant chimney applications, install and
seal a rain cap over existing chimney openings.
13. All piping must be fully supported. Use pipe hangers at a minimum
of 4 foot intervals to prevent sagging of the pipe where condensate
may form.
14. Do not use the heater to support any piping.
15. A screened straight coupling is provided with the heater for use as
an outside exhaust termination.
16. A screened inlet air tee is provided with the heater to be used as an
outside intake termination.
17. Maximum Snow Level Determination: These installation
instructions reference snow levels in establishing a minimum height
for the installation of exhaust vent or air intake terminations. Snow
levels shall be determined as follows:
a. The installation location may, by ordinance, designate how snow
levels are calculated in that location; or
b. In the absence of specic ordinances, snow levels shall be calculated
from the average monthly maximum depth of snow accumulation as
indicated by the National Weather Service’s 10 year statistics for the
installation location/geographical area.
In addition:
Total length of vent piping shall not exceed the limits specied
in this manual.
The vent piping for this direct vented appliance is approved for
zero clearance to combustible construction.
The ue products coming from the exhaust vent will create a
large plume when the heater is in operation. Avoid venting in
areas that will aect neighboring buildings or be considered
objectionable.
DO NOT locate exhaust vent or intake pipe in a parking area
where machinery may damage the pipe.
DO NOT vent near sot vents, crawl space vents, or other areas
where condensate or vapor could create a nuisance or hazard or
cause property damage.
DO NOT vent where condensate vapor could cause damage or
could be detrimental to the operation of regulators, relief valve,
or other equipment.
In the Commonwealth of Massachusetts and as Required by State
and Local Codes:
The vented gas fueled appliance shall not be installed so its combustion,
ventilation, or dilution air is obtained from a bedroom or bathroom.
Signage: Whenever any through-the-wall (horizontal or sidewall) vent
is installed less than seven feet above the nished grade, a metal or
plastic identication plate shall be permanently mounted to the
exterior of the building at a minimum height of eight feet above grade
directly in line with the exhaust vent terminal. The sign shall read, in
print no less than 0.5 inches in size, “GAS VENT DIRECTLY BELOW. KEEP
CLEAR OF ALL OBSTRUCTIONS”.
Marking of Exhaust Vent and Intake Pipe: Piping used for ventilation,
make-up, or combustion air intake shall be labeled as follows:
a. Throughout the entire developed length:
i. Labels must be placed every ten feet for exposed/visible piping; or
ii. Labels must be placed every three feet for concealed piping.
b. At all changes of direction;
c. On each side of a penetration through a partition, wall or ceiling;
and
d. The labels shall be black lettering that:
i. Indicates that the piping is used for ventilation, make-up, or
combustion air intake, and
ii. The letters shall be sized equal to a minimum of the pipe diameter.
However, for piping with a diameter exceeding two inches, said
lettering does not need to be larger than two inches.
The following table lists optional exhaust/intake terminations available
Description Stock Code
3” PVC Concentric Termination Kit KGAVT0601CVT
3” Stainless Steel Termination Kit V1000
4” Stainless Steel Termination Kit V2000
3” Polypro Vent Kit 8400P-001
Table 8 - Optional Vent Kits
G. Applications
1. Indoor Direct Vent Installation of Exhaust and Intake
If installing a direct vent option, combustion air must be drawn
from the outdoors directly into the water heater intake, and exhaust
must terminate outside. There are three basic direct vent options
detailed in this manual: 1. Side Wall Venting, 2. Roof Venting, and 3.
Unbalanced Venting.
Be sure to locate the heater such that the exhaust vent and intake
pipe can be routed through the building and properly terminated.
Dierent vent terminals can be used to simplify and eliminate
multiple penetrations in the building structure (see Optional
Equipment in Venting Section). The exhaust vent and intake pipe
lengths, routing and termination methods must all comply with the
methods and limits given in the Venting section of this manual.
When installing a combustion air intake from outdoors, care must be
taken to utilize uncontaminated combustion air. NOTE: To prevent
combustion air contamination, see Table 2.
Take extra precaution to adequately support the weight of vent
pipes terminating through the roof. Failure to properly support
roof terminated piping could result in property damage, serious
injury, or death.