Amanda WagnerAug 21, 2025
What to do if water pressure is too high in my HTP Water Heater?
- ZzhangrachelAug 22, 2025
If the water pressure is too high, install a pressure reducing valve.
What to do if water pressure is too high in my HTP Water Heater?
If the water pressure is too high, install a pressure reducing valve.
What to do if my HTP Water Heater has no hot water?
If your HTP Water Heater isn't producing any hot water, several factors could be the cause. These include a zone valve not opening (check or replace), a circulator not operating (check or replace), a tank control set too low (raise tank temperature), a boiler control set too low (raise boiler temperature), incorrect wiring (recheck wiring), a tank control failure (replace control), or an air trap in the loop (purge air).
Why is my HTP Water Heater not producing enough hot water?
There could be several reasons why your HTP Water Heater isn't providing enough hot water. These include a zone valve restriction (replace zone valve with a 1” full bore), a reversed circulator arrow (reverse the circulator), or a boiler temperature that is too low (raise the boiler temperature). Other potential causes are: the boiler or tank being too small (check sizing chart), a demand flow rate that is too high (check sizing chart), an air trap in the loop (purge to remove air), the heat and tank coming on together (recheck wiring or coincidence), not enough space heat (boiler sized too small - consult chart), or a slow recovery (circulator head capacity too low).
How to solve zone valve not opening in my HTP SSC-80?
To solve the issue of the zone valve not opening, open it manually to replace it.
What to do if circulator fails in my HTP SSC-80 Water Heater?
If the circulator fails, replace the circulator.
What to do if tank control fails in my HTP SSC-80?
If the tank control fails, replace the control.
What to do if zone valve fails in my HTP SSC-80 Water Heater?
If the zone valve fails, replace the valve.
What to do if water expands when heated in my HTP SSC-80?
If water expands when heated, install an expansion tank.
How to fix air trap in loop of my HTP Water Heater?
To fix an air trap in the loop, purge the air.
What to do if circulator is not operating in my HTP SSC-80 Water Heater?
If the circulator is not operating, check or replace it.
| Brand | HTP |
|---|---|
| Model | SSC-80 |
| Category | Water Heater |
| Language | English |
Mandatory plumbing practices, use of thread tape/dope, and filling procedures to prevent air.
Guidelines for connecting the water heater to the boiler, including circulator installation and pipe sizing.
Requirements for domestic water connections, including dielectric fittings and backflow preventers.
Instructions for connecting the hot water outlet, emphasizing dielectric fittings and care with plastic components.
Critical safety information regarding the installation, testing, and maintenance of T&P relief valves.
Warnings and recommendations for preventing scald injuries from hot water, including mixing valve use.