– targetvalue: specifies the target network segment IP address of the switching plane.
– maskvalue: specifies the subnet mask of the switching plane.
– gatewayvalue: specifies the gateway IP address of the switching plane.
----End
4.4 Logging In to the CLI of Each Switching Plane
Log in to the converged switching plane CLI of the CX320 over Secure Shell (SSH), Serial
Over LAN (SOL), or a serial port.
Log in to the CLI of the converged switching plane for the CX320 by using one of the
following methods:
l Over SSH: Remotely log in to the CLI of the converged switching plane over an
Ethernet.
l Over SOL: Log in to the serial port of the converged switching plane through the
MM910 SOL screen.
l Over a serial port: Connect a serial cable to the COM serial port of the CX320 and log in
to the CLI without using an IP address.
Prerequisites
Data
Table 4-5 Default Data
Name
Default Data Login Method
converged
switching plane
l User name: root
l Password: Huawei12#$
SSH
l No user name
l Password: Huawei12#$
l Serial port
l SOL
Tools
If you want to log in to a server CLI over a serial port, prepare the following hardware:
l PC with an RS232 serial port
l DB9-RJ45 cable
Procedure
l Log in to the CLI of a switching plane over SSH.
Step 1 Connect the local PC to the MM910.
l Connect the network port of the local PC to the MGMT port of the active or standby
MM910.
Figure 4-2 shows the network connections.
CX320 Switch Module
User Guide
4 Configuring the CX320