A.6.1.6 Obtaining the Vendor Log Length
This command is used to obtain the length of vendor logs (including the log parsing package,
full logs, and key logs). Sub_OpType indicates the log type.
Table A-29 Sub_OpType
Sub_OpType
Description
0h Log parsing package
1h Full logs
2h Key logs
3h CoreDump information
The obtained valid log length is returned to the host software as Dword0 in the CQ.
Table A-30 Completion Queue Entry Dword 0
Bit
Description
31:0 Valid log length (unit: byte)
A.6.1.7 Querying the PCB Version
This command is used to obtain the PCB version, which is returned to the host as Dword0 in
the CQ.
Table A-31 Dword0 in the CQ
Bit
Description
31:0 PCB version
A.6.1.8 Obtaining Self-Diagnosis Result
If a bit value is 1, the corresponding item has a fault. If a bit value is 0, the corresponding item
is passed.
Table A-32 CQ-Dword0
Bit
Description
0 Overall test result
ES3000 V3 NVMe PCIe SSD