Node
Name
Node OIDs Description Type Permiss
ion
compositeTe
mperature
1.3.6.1.4.1.2011.2.319.3.1.
10
Overall
temperature
OCTET
STRING
Read-
only
maxCapacity 1.3.6.1.4.1.2011.2.319.3.1.
11
Maximum
capacity
Unsigned32 Read-
only
currentCapac
ity
1.3.6.1.4.1.2011.2.319.3.1.
12
Current
capacity
Unsigned32 Read-
only
dataUnitsRe
ad
1.3.6.1.4.1.2011.2.319.3.1.
13
Total read
data (MB)
OCTET
STRING
Read-
only
dataUnitsWri
tten
1.3.6.1.4.1.2011.2.319.3.1.
14
Total write
data (MB)
OCTET
STRING
Read-
only
availableSpa
re
1.3.6.1.4.1.2011.2.319.3.1.
15
Idle block
rate (%)
Integer32 Read-
only
badBlockRat
e
1.3.6.1.4.1.2011.2.319.3.1.
16
Bad block
rate (%)
OCTET
STRING
Read-
only
percentageU
sed
1.3.6.1.4.1.2011.2.319.3.1.
17
Life used
(%)
Integer32 Read-
only
powerOnHo
urs
1.3.6.1.4.1.2011.2.319.3.1.
18
Total power-
on time (h)
Integer32 Read-
only
capacitanceS
tatus
1.3.6.1.4.1.2011.2.319.3.1.
19
Capacitor
status
OCTET
STRING
Read-
only
powerState 1.3.6.1.4.1.2011.2.319.3.1.
20
Power status OCTET
STRING
Read-
only
writeMode 1.3.6.1.4.1.2011.2.319.3.1.
21
Write mode OCTET
STRING
Read-
only
NOTE
The SNMP system creates a table instance for each SSD. The table node OID is 1(iso).3(org).6(dod).
1(internet).4(private).1(enterprises).2011(huawei).2 (products).319(ES3000V3).3(cardTable).
ES3000 V3 NVMe PCIe SSD
User Guide
C SNMP Function
Issue 20 (2019-02-27) Copyright © Huawei Technologies Co., Ltd. 180