4 
2. Open the chassis door and install the support 
rod available in the fitting bag bound to the 
reinforcing rib at the base of the chassis. 
3. Remove the AC terminal cover. 
4. Remove an appropriate length of the jacket and insulation layer from the AC output cable using 
a wire stripper. 
7. Remove the locking cap from the AC OUTPUT waterproof cable connector at the inverter 
bottom and remove the plug from the locking cap. 
6. Wrap the wire crimp area with heat shrink tubing or PVC insulation tape. 
8. Route the AC output power cable into the locking cap and the AC OUTPUT connector at the 
inverter bottom. 
5. Insert the exposed core wires into the crimp area of the OT terminal and crimp them using 
hydraulic pliers. 
If heat shrink tubing is used, put it through the power cable and then crimp the OT terminal. 
a.   SUN2000-33KTL 
b.   SUN2000-40KTL 
The AC output power cable for the SUN2000-33KTL is a 4-core outdoor cable (L1, L2, L3, and  
N). The AC output power cable for the SUN2000-40KTL is a 3-core outdoor cable (L1, L2, and  
L3).